TESTING AND COMMISSIONING
Testing and commissioning services ensure your equipment and systems are safe and meet critical standards and specifications throughout the lifecycle of your project.- Factory and Site Acceptable Testing and Commissioning
- Power Systems Commissioning
- Switchgear Testing and Commissioning (HV/LV)
- GIS Substation Testing and Commissioning
- High Voltage Components Testing and Commissioning
HIGH VOLTAGE SWITCHGEARS
Sigma Power offers a wide range of maintenance and testing services for GIS and AIS switchgear up to 230kV.- Contact Resistance Test
- Insulation Resistance Test
- Minimum Pick-up Voltage Test
- Breaker timing Tests
- Breaker trip operation through the protective device
- Power and dissipation factor on each pole
- SF6 purity test
- SF6 Leakage test
- SF6 Pressure test
PARTIAL DISCHARGE
A localized electrical discharge that only partially bridges the insulation between conductors and which can or cannot occur adjacent to a conductor” quoted from IEC60270 verbatim.- Corona – discharges to air
- Floating Electrode – metal to metal
- Voids – gaps in solid insulation or cavities as well as gas bubbles in liquid insulation
- Surface Discharge – tracking on the outside surface of insulation traveling towards other conductors or ground
POWER CABLES
Sigma Power offers a broad range of testing and jointing services to give you detailed information about the insulation condition of your power cables.- VLF withstand Test
- VLF Tan Delta Test
- Offline and Online Partial Discharge Test
- Insulation Resistance and Polarisation Index Test
- Sheath Integrity Test
- Fault location and Pin Pointing
- TDR Test
Transformers
Sigma Power offers a wide range of maintenance, testing, condition monitoring, oil analysis, and repair services for the transformers.- Capacitance & Dissipation Factor (C&DF)/Tan Delta/DLA Test
- Transformer Turns Ratio (TTR) Test
- Winding Resistance Test
- Dynamic Resistance Measurement Test
- Tap Changer Analysis
- Vector group identification
- Dirana Test
Rotating Machines
Sigma Power offers a wide range of Rotating Machines testing services for generators and motors insulation condition assessment.- Insulation Resistance & Polarization Index
- Offline and Online Partial Discharge Measurement
- Tan Delta and Capacitance Measurement
- AC/DC Dielectric withstand Voltage Test
- Winding Resistance Test
- Step Voltage Test
- Recurrent Surge Oscillography (RSO) Test
Earth Testing
A well-designed earthing system is the basis for any electrical installation in order to ensure the danger associated with fault currents is avoided, protecting both equipment and personnel.- Earth Grid Impedance
- Step and Touch Potential
- Earth Potential Rise
- Soil Resistivity Testing and Modelling
- Earth Continuity
- Off Grid Current Injection
Protection Relays
A well-designed earthing system is the basis for any electrical installation in order to ensure the danger associated with fault currents is avoided, protecting both equipment and personnel.- Over Current
- Locked Rotor Condition Test
- Test for Loss of Excitation
- Phase Squance Test
- Restricted Earth Fault test
- Over Excitation Test
- Differential Protection Test