The BAUR Frida VLF Test Set is used for cable testing and cable sheath testing, with a maximum test voltage of 26kVrms. The FRIDA is an extremely low frequency tester which has been expertly designed to verify the condition of medium-voltage cables and electrical equipment such as generators and transformers, up to 20kV. VLF testing allows the user to locate insulation faults in plastic and paper-insulated mass-impregnated cables, in quickfire fashion, without impacting the quality of the surround insulating material. Features: • Suitable for continuous operation • Has a maximum test voltage of 26kVrms • Has the following voltage shapes: VLF truesinus, VLF square wave voltage, and DC voltage • Load-independent, reproducible sinusoidal high voltage by means of VLF truesinus testing technology • Cable testing according to: IEC 60060-3, IEC 60502.2, CENELEC HD 620/621 (DIN VDE 0276-620/621), IEEE 400-2012, IEEE 400.2-2013 • Cable sheath testing according to IEC 60502/IEC 60229 • Very low frequency tester for the verification of the condition of medium-voltage cables and electrical equipment up to 20kV • For use with test generators, transformers, and switchgear • Locate faults in plastic-and-paper insulated, mass-impregnated cables • Locate faults with ease and speed without damaging the surrounding materials • Automatic testing and diagnostic sequences • Quick and easy to set up • Transfer data via a USB interface • Automatic discharge unit • Compact and lightweight • A precise, portable and powerful high-voltage testing and diagnostics instrument
-
A discharge stick is a safety device used to safely discharge residual high voltage from equipment like cables, transformers, or capacitors after testing or operation. It typically consists of an insulated shaft, a metal contact tip, an internal resistor, and a grounding cable. The resistor ensures controlled discharge to prevent sudden arcing, while the grounding cable directs the charge safely to earth. Discharge sticks are essential in high voltage testing environments, such as after VLF, DC, or AC withstand tests, to protect personnel from electric shock. Features • Voltage Rating: Up to 60kV, suitable for VLF-tested cables. • Insulated Shaft: Made of fiberglass or epoxy for high dielectric strength. • Internal Resistor: Safely bleeds charge, preventing sudden discharge or arcing. • Grounding Cable: Heavy-duty cable with clamp for secure ground connection. • Contact Tip: Metal hook or probe for reliable contact with test points. • Telescopic Design: Lightweight and portable for field use. • Insulated Grip: Non-slip handle with safety guard ring. • Standards Compliant: Meets IEC/ASTM safety standards.
-
The most advanced HV test system available, with the highest output power of any unit available. Lightest, most compact instrument of its type available with control cabinet and HV generator all contained in one box. Offering variable frequency VLF output for testing of HV Cables and Switchgear, the operator can also select dual polarity DC and cable jacket or sheath testing output modes. The applied test voltage, current, capacitance, resistance and time are displayed and recorded. Easily programmable allowing test sequences in either automatic or manual mode. Capable of testing approx 3000m of cable at 0.1Hz and 60kV peak. At 0.02Hz, approx. 15,000m of cable can be tested. Features: • It’s expertly designed to be easily transported and used in various locations, from in-field testing sites to industrial labs. Its high power-to-weight ratio is unparalleled in the industry, providing great performance in a conveniently small package. • HVA60 can be extended to a complete cable diagnostic system at any time. • HVA test sets are constructed with non-arcing contacts and no need to change oil. This eliminates routine servicing and makes the test sets almost maintenance-free. • HVA generators are designed for continuous operation without any thermal limitations. • Pure sinusoidal output voltage (load-independent) • Breakdown voltage and load detection • Report downloads from the device via USB flash drive
-
The PFT-503CM(F) AC hipot test set provides continuously adjustable output voltages for overvoltage withstand testing of the following: Switchgear, Circuit breakers, Reclosers, Vacuum bottles, Hot sticks, Motor windings and other high voltage insulation requiring AC. Features: • Convenient one-piece field portable design • Secondary connected 2 Range Voltmeter: 0 - 25 / 50 kV AC • 3 Range Current Meter: 0 – 1 mA AC with x1, x10, and x100 multipliers • Fixed overload set to 120% of variable transformer rated output current • Transit protected meters prevent meter damage between test sites • Guard/Ground circuit for accurate leakage current measurement • 20 ft shielded output and return cables • Gapped core transformer design for capacitive load compensation • Zero Start and External safety Interlock provisions
-
Elbow branch connector made of silicone rubber for connection up to 42 kV XLPE-cables to outercone bushing type C1 (630A) and C2 (1250A) according to EN 50180 and 50181. Features: Max. cross section: 400 mm². Core type: Single-Core, Three-Core. Max. operating Voltage (Ur): 42 kV. Application: Switch Gear, Transformer.
-
Made of a highly modified silicone rubber and protected by a thin-walled outer conductive screen connected to earth, connectors are equally suited for indoor and outdoor installation. Supporting a wide application range, the design incorporates one body and two stress cone adapters to cover all cross-sections from 25 to 300 mm2. The overall and cut-back dimensions are designed to take up minimum space in the terminal box. The connectors are equipped with a capacitive test point for determining whether the circuit is energised. This test point is protected by a conductive cap. After cable preparation and lubrication, the stress control adapter is simply slid into place, followed by the screened connector body. These two components can be installed under virtually any conditions. Features: • The insulation of the connector is made of a highly modified silicone rubber characterised by high tracking resistance, elongation at break and non-flammability. • A thin-walled screen is permanently bonded onto the insulation and protects the connection system against unintentional contact. • The screened connector need not be removed for oversheath testing. • The screened cable connector exceeds CENELEC HD 629.1 S2 requirements, which includes BS, VDE and other international specifications. • Design fits 630/1250 A bushings type “C” as specified by EN50180 and EN50181. • The compact design supports the use of double “T” connections inside standard terminal boxes. • The wide application range covers cable cross-sections from 25 to 300 mm2. • Conductor connection with mechanical or DIN lugs. • Easily accessible rear plug with capacitive test point. • Few accessories required for system test, double “T” and earth connection. • Complete kit including lugs facilitates installation and storage.
-
The BAUR Shirla system is designed for efficient testing and fault location in both power and control cables, including cable sheaths. It supports comprehensive fault diagnostics through pre-location and pinpointing techniques. The system uses the Murray and Glaser bridge methods for fault pre-location, which are particularly effective for power cables, but also suitable for control and lighting cables. The measurement process is automated, including null balancing and result evaluation. Features: • Cable and sheath testing up to 10 kV DC • High-accuracy resistance measurement • Precise fault pre-location using a measuring bridge • Customisable cable parameters (length, cross-section, material) for accurate distance calculations