Transformer Test Set2025-04-07T23:06:09+00:00
Home/Equipment Hire/Transformer Test Set

Transformer Test Sets for Comprehensive Performance Testing

  • The OMICRON CP TD12 is a precision test accessory used with the CPC 100 for measuring capacitance and dissipation factor (tan delta) on high-voltage electrical insulation systems. It is ideal for condition assessment of assets like power transformers, bushings, cables, and rotating machines. Key Features: • Accurate measurement of capacitance and dissipation factor (tan delta) • Test voltage up to 12 kV AC • Wide measurement range for insulation testing • Fully automated and integrated with CPC 100 and PTM software • Compact and portable design, suitable for field use • High accuracy and repeatability for reliable diagnostics • Supports ungrounded and grounded specimen testing Typical Applications: • Insulation condition assessment of power transformers and bushings • Tan delta and capacitance testing of cables and rotating machines • Detection of moisture, aging, and contamination in insulation • Quality assurance during commissioning and maintenance • High voltage testing up to 12 kV in the field or laboratory  
    Details
  • The OMICRON CPC 100 is a versatile and powerful testing device for primary electrical equipment in substations. It can be used to test current transformers (CTs), voltage transformers (VTs), power transformers, circuit breakers, protection relays, and grounding systems. It replaces multiple individual testing devices, making field testing more efficient and convenient. Features: •  Universal testing for CTs, VTs, power transformers, circuit breakers, relays, and grounding systems •  Provides up to 800 A or 2000 V output power (5 kVA) without the need for external amplifiers • Compact, lightweight, and designed for easy transport and use in the field • High measurement accuracy with built-in safety features • Automated test sequences for faster and more reliable testing • Compatible with Primary Test Manager (PTM) software for data handling, test planning, and reporting • Performs insulation resistance, ratio, polarity, burden, and phase angle tests Typical Applications: • Testing current transformers (CTs) • Testing voltage transformers (VTs) • Testing power transformer winding resistance, turns ratio, and vector group • Circuit breaker timing and travel testing • Grounding system impedance measurement • Primary injection testing of protection relays
    Details
  • The OMICRON TESTRANO 600 is a multifunctional, portable device designed for fast and efficient three-phase power transformer testing. It combines multiple tests in one unit, reducing setup time and improving reliability during condition assessments of power transformers. Key Features: •  All-in-one solution for transformer testing (winding resistance, turns ratio, vector group, and more) •  Three-phase test system for simultaneous measurements •  Single connection setup for all major electrical test. •  Up to 400 A DC test current and up to 250 V AC test voltage •  Integrated demagnetization function after resistance testing •  Fully automated test sequences via Primary Test Manager (PTM) software •  Compact and portable design for convenient field use •  High accuracy and repeatability Typical Applications: •  Winding resistance measurement (single and three-phase) •  Turns ratio and vector group verification •  Magnetization current and short-circuit impedance testing • Transformer core demagnetization • Dynamic resistance measurement (DRM) on OLTCs • Fast condition assessment during commissioning or maintenance
    Details
Back to Equipment Hire
Go to Top